La imagen puede ser una representación.
Consulte las especificaciones para obtener detalles del producto.
MAX706TCUA+

MAX706TCUA+ - English Editing Encyclopedia Entry

Product Overview

Category

MAX706TCUA+ belongs to the category of integrated circuits (ICs).

Use

This product is commonly used in electronic devices for voltage monitoring and reset functions.

Characteristics

  • Voltage monitoring and reset functionality
  • Low power consumption
  • Wide operating voltage range
  • Small package size
  • High accuracy

Package

MAX706TCUA+ is available in a small-sized micro SMD package.

Essence

The essence of this product lies in its ability to monitor voltage levels and provide a reset signal when necessary, ensuring proper functioning of electronic devices.

Packaging/Quantity

This product is typically packaged in reels or tubes, with a quantity of 250 units per reel/tube.

Specifications

  • Supply Voltage Range: 1.6V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Reset Threshold Voltage Options: 2.63V, 3.08V, 4.38V, and adjustable
  • Reset Timeout Period Options: 140ms, 560ms, and adjustable
  • Quiescent Current: 7µA (typical)

Detailed Pin Configuration

The MAX706TCUA+ has the following pin configuration:

  1. GND (Ground)
  2. MR (Master Reset)
  3. RESET (Reset Output)
  4. VCC (Supply Voltage)

Functional Features

  • Voltage Monitoring: The MAX706TCUA+ continuously monitors the supply voltage and compares it with the preset threshold voltage.
  • Reset Generation: When the supply voltage falls below the threshold voltage, the MAX706TCUA+ generates a reset signal to initiate a system reset.
  • Adjustable Parameters: The reset threshold voltage and timeout period can be adjusted according to specific application requirements.
  • Power-On Reset: The device provides a reset signal upon power-up to ensure a controlled start-up of the system.

Advantages and Disadvantages

Advantages

  • High accuracy in voltage monitoring
  • Low power consumption
  • Wide operating voltage range allows for versatile applications
  • Small package size enables space-saving designs

Disadvantages

  • Limited number of preset threshold voltage options
  • Adjustable parameters may require additional configuration efforts

Working Principles

The MAX706TCUA+ operates by continuously monitoring the supply voltage using an internal voltage comparator. When the voltage falls below the preset threshold, the device generates a reset signal. The reset signal remains active until the supply voltage rises above the threshold and the timeout period elapses.

Detailed Application Field Plans

The MAX706TCUA+ finds application in various electronic devices that require voltage monitoring and reset functionality. Some common application fields include:

  1. Microcontrollers: Ensuring proper operation and system integrity during power fluctuations.
  2. Embedded Systems: Providing reliable reset signals to prevent system malfunctions.
  3. Industrial Automation: Monitoring voltage levels in control systems to maintain stability and safety.
  4. Automotive Electronics: Resetting microcontrollers and sensors in case of voltage drops or disturbances.
  5. Power Supply Units: Protecting sensitive components from voltage variations and ensuring stable output.

Detailed and Complete Alternative Models

  1. MAX705ESA+: Similar to MAX706TCUA+, but available in a different package (SOIC).
  2. MAX707EPA+: Offers additional features such as adjustable reset timeout period.
  3. MAX708SESA+: Provides a wider range of preset threshold voltage options.

These alternative models offer similar functionality and can be considered based on specific application requirements.

Word count: 530 words

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de MAX706TCUA+ en soluciones técnicas

Sure! Here are 10 common questions and answers related to the application of MAX706TCUA+ in technical solutions:

  1. Q: What is the MAX706TCUA+? A: The MAX706TCUA+ is a microprocessor supervisory circuit that monitors the power supply voltage of a system and provides reset signals to the microcontroller when necessary.

  2. Q: What is the operating voltage range of MAX706TCUA+? A: The operating voltage range of MAX706TCUA+ is typically between 1.8V and 5.5V.

  3. Q: How does MAX706TCUA+ ensure reliable system operation? A: MAX706TCUA+ monitors the power supply voltage and generates a reset signal to the microcontroller if the voltage falls below a certain threshold, ensuring proper system initialization.

  4. Q: Can MAX706TCUA+ be used with different microcontrollers? A: Yes, MAX706TCUA+ can be used with a wide range of microcontrollers as long as the operating voltage requirements are within its specified range.

  5. Q: Does MAX706TCUA+ have any adjustable parameters? A: No, MAX706TCUA+ does not have any adjustable parameters. It operates based on fixed voltage thresholds.

  6. Q: Can MAX706TCUA+ be used in battery-powered applications? A: Yes, MAX706TCUA+ can be used in battery-powered applications as it has a low quiescent current consumption, making it suitable for power-sensitive designs.

  7. Q: What is the typical reset timeout period of MAX706TCUA+? A: The typical reset timeout period of MAX706TCUA+ is around 140ms, ensuring sufficient time for the microcontroller to stabilize after power-up.

  8. Q: Can MAX706TCUA+ be used in automotive applications? A: Yes, MAX706TCUA+ is suitable for automotive applications as it can operate within the specified temperature range and has built-in protection features.

  9. Q: Does MAX706TCUA+ have any additional features apart from voltage monitoring? A: Yes, MAX706TCUA+ also includes a manual reset input and a watchdog timer to further enhance system reliability.

  10. Q: What is the package type of MAX706TCUA+? A: MAX706TCUA+ is available in a small 8-pin µMAX package, which is compact and suitable for space-constrained designs.

Please note that these answers are general and may vary depending on the specific application and requirements.