MAX805REPA+ - English Editing Encyclopedia Entry

Product Overview

Category

MAX805REPA+ belongs to the category of electronic components.

Use

The MAX805REPA+ is primarily used as a voltage supervisor and reset circuit in various electronic devices.

Characteristics

  • Voltage supervisor with reset output
  • Low supply current
  • Wide operating voltage range
  • Adjustable reset threshold
  • Active-low reset output
  • Small package size

Package

The MAX805REPA+ is available in a small 8-pin PDIP package.

Essence

The essence of MAX805REPA+ lies in its ability to monitor the supply voltage and generate a reset signal when the voltage falls below a certain threshold.

Packaging/Quantity

The MAX805REPA+ is typically packaged in reels or tubes, with a quantity of 250 units per reel/tube.

Specifications

  • Supply Voltage Range: 1.0V to 5.5V
  • Reset Threshold Voltage: Adjustable from 1.2V to VCC-0.6V
  • Reset Timeout Period: Fixed at 140ms (min)
  • Quiescent Current: 7µA (typ)
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The MAX805REPA+ has the following pin configuration:

```


| | --| RESET |-- --| GND |-- --| MR |-- --| VCC |-- --| RESET_OUT |-- --| THRESHOLD |-- --| GND |-- |___________| ```

Functional Features

  • Voltage monitoring: The MAX805REPA+ continuously monitors the supply voltage.
  • Reset generation: When the supply voltage drops below the set threshold, the MAX805REPA+ generates a reset signal.
  • Adjustable threshold: The reset threshold voltage can be adjusted to suit specific application requirements.
  • Active-low reset output: The reset output is active low, indicating a system reset condition.
  • Low supply current: The MAX805REPA+ operates with low quiescent current, minimizing power consumption.

Advantages and Disadvantages

Advantages

  • Wide operating voltage range allows compatibility with various systems.
  • Adjustable reset threshold provides flexibility in different applications.
  • Small package size enables space-saving designs.
  • Low supply current minimizes power consumption.

Disadvantages

  • Fixed reset timeout period may not be suitable for all applications.
  • Limited pin configuration options may restrict certain circuit designs.

Working Principles

The MAX805REPA+ works by comparing the supply voltage with the set threshold voltage. When the supply voltage drops below the threshold, the internal circuitry generates a reset signal. This signal remains active until the supply voltage rises above the threshold and the reset timeout period elapses.

Detailed Application Field Plans

The MAX805REPA+ finds applications in various electronic devices, including: 1. Microcontrollers and microprocessors 2. Embedded systems 3. Power management circuits 4. Battery-powered devices 5. Industrial control systems

Detailed and Complete Alternative Models

  1. MAX809REUR+: Similar to MAX805REPA+, but with a push-pull reset output.
  2. MAX811TEUS-T: Voltage supervisor with adjustable reset threshold and watchdog timer.
  3. MAX803TEXR+: Ultra-low-power voltage supervisor with manual reset input.

These alternative models offer similar functionality and can be considered as substitutes for the MAX805REPA+ in different applications.

Word count: 510 words

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de MAX805REPA+ en soluciones técnicas

  1. Question: What is the MAX805REPA+?
    Answer: The MAX805REPA+ is a voltage supervisor and reset IC manufactured by Maxim Integrated. It is commonly used in technical solutions to monitor power supply voltages and provide a reset signal when necessary.

  2. Question: What is the operating voltage range of the MAX805REPA+?
    Answer: The MAX805REPA+ operates within a voltage range of 1.8V to 5.5V.

  3. Question: How does the MAX805REPA+ monitor power supply voltages?
    Answer: The MAX805REPA+ compares the monitored voltage with a preset threshold. If the voltage drops below the threshold, it triggers a reset signal.

  4. Question: Can the threshold voltage be adjusted in the MAX805REPA+?
    Answer: No, the threshold voltage in the MAX805REPA+ is fixed at a specific value.

  5. Question: What is the typical reset timeout period of the MAX805REPA+?
    Answer: The typical reset timeout period of the MAX805REPA+ is 140ms.

  6. Question: Is the MAX805REPA+ capable of providing an active-low or active-high reset signal?
    Answer: Yes, the MAX805REPA+ can be configured to provide either an active-low or active-high reset signal, depending on the application requirements.

  7. Question: What is the maximum supply current required by the MAX805REPA+?
    Answer: The maximum supply current required by the MAX805REPA+ is typically 10µA.

  8. Question: Can the MAX805REPA+ be used in battery-powered applications?
    Answer: Yes, the low supply current requirement of the MAX805REPA+ makes it suitable for battery-powered applications.

  9. Question: Does the MAX805REPA+ have any built-in protection features?
    Answer: Yes, the MAX805REPA+ includes features like reverse battery protection and thermal shutdown to protect against potential issues.

  10. Question: What package options are available for the MAX805REPA+?
    Answer: The MAX805REPA+ is available in a 8-pin PDIP and SOIC package options.