The MAX861CUA+ belongs to the category of integrated circuits (ICs).
This product is primarily used for biomedical applications, specifically in the field of optical heart rate monitoring and pulse oximetry.
The MAX861CUA+ is available in a small 8-pin µMAX package, which ensures compactness and ease of integration into various devices.
The essence of this product lies in its ability to enable non-invasive monitoring of vital signs, such as heart rate and blood oxygen levels, through optical sensing technology.
The MAX861CUA+ is typically sold in reels or tubes, with a quantity of 250 units per reel/tube.
The MAX861CUA+ features the following pin configuration:
The MAX861CUA+ utilizes the principles of photoplethysmography (PPG) to measure heart rate and blood oxygen saturation levels. It emits light from the integrated LEDs onto the skin and detects the reflected light using the photodetectors. By analyzing the variations in the intensity of the reflected light caused by blood flow, the IC can accurately determine the heart rate and blood oxygen levels.
The MAX861CUA+ is widely used in various applications, including:
In conclusion, the MAX861CUA+ is a highly integrated IC designed for optical heart rate monitoring and pulse oximetry applications. With its compact design, low power consumption, and accurate measurements, it finds extensive use in various wearable devices and portable medical equipment.
Sure! Here are 10 common questions and answers related to the application of MAX861CUA+ in technical solutions:
Q: What is the MAX861CUA+? A: The MAX861CUA+ is a highly integrated optical sensor module that combines three key biosensors - a photoplethysmogram (PPG) front-end, an electrocardiogram (ECG) front-end, and an optical pulse oximeter.
Q: What are the main applications of the MAX861CUA+? A: The MAX861CUA+ is commonly used in wearable devices, fitness trackers, health monitoring systems, and medical devices for measuring heart rate, blood oxygen saturation, and other vital signs.
Q: How does the MAX861CUA+ measure heart rate? A: The MAX861CUA+ uses the PPG front-end to detect changes in blood volume by illuminating the skin with LEDs and measuring the reflected light. It then calculates the heart rate based on these measurements.
Q: Can the MAX861CUA+ measure blood oxygen saturation (SpO2)? A: Yes, the MAX861CUA+ includes an optical pulse oximeter that can measure blood oxygen saturation levels non-invasively by analyzing the absorption of red and infrared light.
Q: Is the MAX861CUA+ suitable for continuous monitoring of vital signs? A: Yes, the MAX861CUA+ is designed for continuous monitoring applications and provides real-time data for heart rate, SpO2, and other parameters.
Q: What is the power supply requirement for the MAX861CUA+? A: The MAX861CUA+ operates from a single power supply voltage ranging from 1.7V to 3.3V, making it compatible with a wide range of battery-powered devices.
Q: Can the MAX861CUA+ communicate with other devices or microcontrollers? A: Yes, the MAX861CUA+ features an I2C interface that allows it to communicate with external devices or microcontrollers for data transfer and control.
Q: Does the MAX861CUA+ provide any built-in motion artifact detection? A: Yes, the MAX861CUA+ includes integrated algorithms for motion artifact detection and removal, ensuring accurate measurements even during physical activities.
Q: What is the typical accuracy of heart rate and SpO2 measurements with the MAX861CUA+? A: The MAX861CUA+ provides high accuracy heart rate and SpO2 measurements, typically within ±2 bpm for heart rate and ±2% for SpO2.
Q: Are there any evaluation kits available for the MAX861CUA+? A: Yes, Maxim Integrated offers evaluation kits that include the MAX861CUA+ sensor module along with software tools and documentation to facilitate development and testing.
Please note that these answers are general and may vary depending on specific implementation and use cases.